1. Identification
2. Hazard Identification
Classification: Article (sealed lithium‑ion battery). Not classified as hazardous under normal conditions of use. Internal contents are hazardous if released.
Primary hazards: Fire, thermal runaway, venting, or burns if short‑circuited, crushed, overcharged, heated > 65 °C (149 °F), or incinerated.
Label elements (recommended): CAUTION — Risk of Fire and Burns. Do Not Open, Crush, Heat Above 65 °C (149 °F) or Incinerate. Follow Manufacturer’s Instructions.
3. Composition / Information on Ingredients
Component | Specification |
---|---|
Li‑ion cell | Model 126280; 10 000 mAh; 3.85 V nominal; max charge voltage 4.4 V |
Battery pack | 1S1P configuration with protection (PCM/BMS) |
Circuit module | Charge/discharge control; limited power source compliance |
Enclosure | Non‑metallic housing |
4. First Aid Measures
- Inhalation (vented cells): Move to fresh air. Seek medical attention if symptoms persist.
- Skin contact: Wash with soap and water. Remove contaminated clothing.
- Eye contact: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do. Seek medical advice for irritation.
- Ingestion: Do not induce vomiting. Rinse mouth. Get medical attention immediately.
5. Firefighting Measures
- Suitable extinguishing media: Dry chemical, CO₂, foam, water spray.
- Specific hazards: Thermal runaway may release flammable/toxic gases.
- Protective equipment: Firefighters should wear self‑contained breathing apparatus (SCBA).
6. Accidental Release Measures
For damaged or leaking cells: ventilate area, avoid breathing vapors, wear gloves/eye protection, collect residues with inert absorbent and place in approved container for disposal.
7. Handling and Storage
- Do not disassemble, crush, short the terminals, immerse in liquids, or expose to open flame.
- Store cool, dry, well‑ventilated. Avoid > 65 °C (149 °F). Charge 0–45 °C; discharge per device guidance.
- Use only with compatible devices and cables. Follow user manual.
8. Exposure Controls / Personal Protection
No exposure expected during normal use. For handling damaged units, wear safety glasses and gloves; use local exhaust ventilation.
9. Physical and Chemical Properties
10. Stability and Reactivity
Stable under normal handling. Avoid heat > 65 °C, sparks, open flame, crushing, puncture, or incompatible chargers. Hazardous decomposition: carbon oxides and irritating/toxic fumes in fire.
11. Toxicological Information
No toxicity during normal use. Electrolyte and decomposition products may be harmful if released or inhaled.
12. Ecological Information
Avoid uncontrolled release. Do not dispose in environment or household trash. Recycle via authorized e‑waste channels.
13. Disposal Considerations
Dispose/recycle in accordance with local, regional, and national regulations. Do not incinerate. Tape terminals before transport.
14. Transport Information
Follow current IATA/ICAO, IMDG, and 49 CFR requirements. Packaging/marking vary by quantity and state of charge.
15. Regulatory Information
Evaluated to UL 2056:2020 (Safety of Power Banks). Tests included insulation, temperature management, limited power source, vibration/shock, short‑circuit/overload, and overcharge. All samples met criteria per report DN‑25022804R.
16. Other Information
Source: Shenzhen DL New Energy Testing Technology Co., Ltd. test report DN‑25022804R (Issue date: 2025‑03‑08). This SDS is provided for guidance for a sealed article and does not certify regulatory compliance in any jurisdiction. Replace the “Supplier / Distributor” field with your company details before publishing.